  Datasheet File OCR Text:
  temperature coefcient 0.03% / c typical. emi/em compliance all models include built-in emi fltering to meet the following emc requirements of iec601-1-2. ac input 90-264 vac, 47-63 hz single phase. class i or class ii grounding. input current maximum input current at 90 vac, 60 hz with full rated output load not to exceed 0.6 a. input protection internal ac fuse provided on all units. designed to blow only if a catastrophic failure occurs in the unit -- fuse does not blow on unsustained overload or short circuit. inrush current inrush is limited by internal thermistors. the inrush at 240 vac, averaged over the frst ac half-cycle under cold start conditions will not exceed 37 a. efciency 69-85% depending on model. overload protection fully protected against short circuit and output overload. short circuit protec - tion is cycling type power limit. factory set to begin power limiting at 23 w. overvoltage protection built in ovp on all models. approximately 120-140% of output voltage. output noise 0.5% rms, 1% pk-pk, 20 mhz bandwidth, diferential mode. measured with noise probe directly across output terminals of the power supply. transient response main output - 500 s max. response time for return to within 0.5% of fnal value for a 50% load step change, ?i/ ?t< 0.2 a/s. maximum voltage devia - tion is 3.5%. hold-up time 10 ms minimum from loss of ac input voltage at full load, nominal line (120 vac). GSM15 medical 15 watt global performance medical switcher ?findustrysfsmallestf15fwfmedicallyfapprovedfswitcher ?fcompactfsizef(3.00fxf2.10fxf0.92) ?fwide-rangefacfinput:f90-264fvac ?flessfthanf75fafleakagefcurrentf@f120fvac ?fapprovedftoful2601-1,fen60601-1 ?femiftoffcc,fcisprf11fclassfb ?fovervoltagefprotectionfstandard ?frohsfcompliantfmodelsfavailablef(gfsufx) global performance switchers all specifcations are typical at nominal input, full load at 25 o c unless otherwise stated features: d c p o w e r s u p p l i e s ffspecifications ?fffffffffmarkedftoflvd medical safety approvals all models are certifed to be in compliance with the applicable requirements of ul2601-1, iec60601-1, csa-c22.2 no. 601-1, en60601-1. leakage current the maximum leakage current for GSM15 series will be as follows; performance requirement emc standard typical margin conducted emissions en55011, class b; fcc class b 2 db class ii gnd 6 db class i gnd surge discharge en61000-4-2, level 3 2 kv rf field susceptibility en61000-4-3, level 3 2 v fast transients/bursts en61000-4-4, level 3 500 v surge susceptibility en61000-4-5, level 3 500 v conducted rf susceptibility en61000-4-6 25% voltage sags & surges en61000-4-11 5% 132vac/60hz ul2601-1 test method gnd connection normal single fault class i 75 a 105 a class ii 39 a 54 a 264vac/50hz iec60601-1 test method gnd connection normal single fault class i 128 a 180 a class ii 66 a 94 a
sl power electronics corp., 6050 king drive, bldg. a, ventura, ca 93003, usa. phone:(805) 486 4565 fax:(805) 487 8911 www.slpower.com rev. 1/07. data sheet ? 2007 sl power electronics corp. the information and specifcations contained in this data sheet are believed to be correct at time of publication. however, condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. specifcations are subject to change without notice. environmentalffspecifications operating non-operating temperature (a) 0 to 50 c -40 to +85c humidity (a) 0 to 95% rh 0 to 95% rh shock (b) 20 g pk 40 g pk altitude -500 to 10,000 ft -500 to 40,000 ft vibration (c) 1.5 g rms 0.003 g 2 /hz 5 g rms 0.026 g 2 /hz fGSM15fmechanicalfspecifications a. units should be allowed to warm up/operate under non-condensing conditions before application of power. b. shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, total 6 shocks. c. random vibration10 to 2000hz, 6db/octave roll-of from 350 to 2000hz, 3 orthogonal axes. tested for 10 min./axis operating and 1 hr./axis non-operating. medicalf f model voltagef f output f min. f normalf(a) f peakf(b) initialfsetf point f ovpfsetpoint totalf f regulation ripplefandf noise GSM15-5 5.1 v 0 a 2.35 a 3 a 2.5% 7.2 v 2% 1% GSM15-12 12 v 0 a 1.25 a 1.5 a 2.5% 16 v 2% 1% GSM15-15 15 v 0 a 1.0 a 1.2 a 2.5% 21 v 2% 1% GSM15-24 24 v 0 a 0.625 a 0.75 a 2.5% 32 v 2% 1% GSM15-28 28 v 0 a 0.54 a 0.64 a 2.5% 280 v 2% 1% notes: a. rating with unrestricted convection cooling. b. peak power for 60 sec. 10% duty cycle or continuous rating with 150 lfm of airfow. c. output voltages preset at factory, not user adjustable. d. add g sufx to model nuber for rohs compliant model. input: j1 amp p/n 640456-4 pin 1) ac line pin 2) n/c pin 3) n/c pin 4) ac neutral gnd: 0.098 dia. thru hole output: j2 amp p/n 640456-4 pin 1) common return pin 2) common return pin 3) output #1 + vout pin 4) output#1 +vout mating connector amp p/n mta C 100 recepticle note: 3a maximum recommended current per connector pin overall dimensions: 3.00 x 2.10 x .92 inches 76.20mm x 53.34mm x 23.37mm weight: 0.25 lbs. [.113 kg] max.


▲Up To Search▲   

 
Price & Availability of GSM15

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X